316L SS for Downhole Chemical Injection lines

0 votes
Hello,

Husky is reviewing the idea of using 316L SS for DownHole Chemical Injection (DHCI) capillary lines, rather than the 825 alloy we currently use.  The line is used to inject scale inhibitor downhole at low rates.  We intend to do corrosion testing with our current scale inhibitor, however don’t want to overly limit ourselves from other / future products on the market.  Does anyone have experiences, good or bad, using 316L SS for downhole chemical injection lines?

Thanks,

Dan Schoonhoven
asked Jun 5 in WTN by Dan Schoonhoven (390 points)